{"id":147889,"date":"2026-02-12T10:11:48","date_gmt":"2026-02-12T09:11:48","guid":{"rendered":"https:\/\/aiguasol.coop\/?post_type=portfolio&#038;p=147889"},"modified":"2026-04-22T09:48:42","modified_gmt":"2026-04-22T07:48:42","slug":"lampliacio-de-lauditori-maestro-padilla-una-estrategia-en-eficiencia-energetica-i-sostenibilitat","status":"publish","type":"portfolio","link":"https:\/\/aiguasol.coop\/ca\/project\/lampliacio-de-lauditori-maestro-padilla-una-estrategia-en-eficiencia-energetica-i-sostenibilitat\/","title":{"rendered":"L\u2019ampliaci\u00f3 de l\u2019Auditori Maestro Padilla: una estrat\u00e8gia en efici\u00e8ncia energ\u00e8tica i sostenibilitat"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=\u00bb1\/1&#8243;][vc_column_text uncode_shortcode_id=\u00bb167243&#8243;]<span style=\"font-weight: 400;\">L\u2019ampliaci\u00f3 de l\u2019Auditori Municipal Maestro Padilla a Almeria, desenvolupada en col\u00b7laboraci\u00f3 amb <\/span><a href=\"https:\/\/abalosllopis.com\/\"><b>\u00c1balosllopis Arquitectura<\/b><\/a><span style=\"font-weight: 400;\"> i promoguda per l\u2019<\/span><a href=\"https:\/\/almeriaciudad.es\/\"><b>Ajuntament d\u2019Almeria<\/b><\/a><span style=\"font-weight: 400;\">, representa un pas decisiu cap a una arquitectura cultural m\u00e9s sostenible, eficient i alineada amb els reptes clim\u00e0tics actuals. Amb una superf\u00edcie constru\u00efda total de 3.663,51 m\u00b2 \u2014que inclou 3.026,25 m\u00b2 de nova edificaci\u00f3 i 637,26 m\u00b2 de reforma de l\u2019edifici existent\u2014, el projecte no nom\u00e9s amplia la capacitat i funcionalitat de l\u2019equipament, sin\u00f3 que el transforma en un edifici d\u2019altes prestacions energ\u00e8tiques.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A Aiguasol hem liderat el disseny integral de les instal\u00b7lacions de l\u2019edifici amb un enfocament clar: <\/span><b>minimitzar el consum energ\u00e8tic, maximitzar l\u2019\u00fas d\u2019energies renovables i garantir el confort i la qualitat ambiental interior de l\u2019espai.<\/b><\/p>\n<h3><b>Enginyeria al servei de la descarbonitzaci\u00f3<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">La nostra feina com a soci estrat\u00e8gic del projecte ha abarcat des de la fase d\u2019an\u00e0lisi i optimitzaci\u00f3 energ\u00e8tica fins al desenvolupament complet del projecte executiu de les instal\u00b7lacions, incloent:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019optimitzaci\u00f3 energ\u00e8tica i l\u2019an\u00e0lisi d\u2019alternatives de les instal\u00b7lacions de climatitzaci\u00f3 i ventilaci\u00f3.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">La certificaci\u00f3 energ\u00e8tica de l\u2019edifici.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">El projecte executiu de les instal\u00b7lacions de climatitzaci\u00f3, ventilaci\u00f3, energia fotovoltaica, electricitat, lampisteria i sanejament, protecci\u00f3 contra incendis, veu i dades.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019an\u00e0lisi de viabilitat sobre un sistema de reg amb dip\u00f2sit de tempestes per a la zona del Palmeral.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">El projecte executiu d\u2019instal\u00b7laci\u00f3 de lampisteria, reg, sanejament, electricitat, gas i telecomunicacions de la Urbanitzaci\u00f3 i del Palmeral associat.<\/span><\/li>\n<\/ul>\n<h3><b>Un sistema clim\u00e0tic renovable i d\u2019alt rendiment<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Un dels pilars del projecte ha estat el disseny d\u2019un sistema de climatitzaci\u00f3 avan\u00e7at basat en fonts renovables i tecnologies d\u2019alta efici\u00e8ncia.<\/span><\/p>\n<p><b>Simulaci\u00f3 energ\u00e8tica avan\u00e7ada<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\">Les necessitats t\u00e8rmiques de l\u2019edifici es van calcular amb el programari DesignBuilder, recolzat en el motor de c\u00e0lcul din\u00e0mic EnergyPlus, realitzant simulacions hor\u00e0ries al llarg d\u2019un any clim\u00e0tic representatiu d\u2019Almeria (fitxer Meteonorm 7). Aix\u00f2 va permetre dimensionar amb precisi\u00f3 les instal\u00b7lacions i evitar sobredimensionaments innecessaris.<\/span><\/p>\n<p><b>Sistema h\u00edbrid de producci\u00f3 t\u00e8rmica<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> L\u2019edifici combina:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Geot\u00e8rmia, com a sistema base d\u2019alta efici\u00e8ncia.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Aerot\u00e8rmia, per cobrir els pics de demanda en els moments de major ocupaci\u00f3 i en condicions clim\u00e0tiques extremes, especialment a l\u2019estiu.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Aquest plantejament h\u00edbrid optimitza el rendiment global del sistema i redueix significativament les emissions de CO\u2082.<\/span><\/p>\n<p><b>Unitats de Tractament d\u2019Aire (UTA) d\u2019alta efici\u00e8ncia<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> S\u2019han projectat 5 UTAs amb:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Sistema de 4 tubs (fred i calor simultani)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Recuperaci\u00f3 d\u2019energia de l\u2019aire d\u2019extracci\u00f3<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Free-cooling quan les condicions exteriors ho permeten<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Aix\u00f2 garanteix confort t\u00e8rmic estable durant tot l\u2019any (26\u202f\u00b0C a l\u2019estiu i 21\u202f\u00b0C a l\u2019hivern), alhora que minimitza el consum energ\u00e8tic.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\">Per a aules i sales d\u2019assaig, s\u2019ha optat per una soluci\u00f3 mixta d\u2019UTA d\u2019aire primari combinada amb fan-coils de 4 tubs per estan\u00e7a, permetent un control prec\u00eds i zonificat de la climatitzaci\u00f3.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b>Aigua calenta sanit\u00e0ria (ACS) amb aerot\u00e8rmia<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">En lloc d\u2019un sistema centralitzat amb llargues xarxes de distribuci\u00f3, s\u2019han instal\u00b7lat acumuladors aut\u00f2noms d\u2019ACS amb bomba de calor aerot\u00e8rmica integrada als vestidors i lavabos dels camerinos.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Cada equip compta amb:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">270 litres d\u2019acumulaci\u00f3<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Bomba de calor de 2,4 kW<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Resist\u00e8ncia el\u00e8ctrica de suport de 1,5 kW<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u00c0node electr\u00f2nic anticorrosi\u00f3<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Aquesta soluci\u00f3 redueix p\u00e8rdues t\u00e8rmiques, millora l\u2019efici\u00e8ncia i garanteix un subministrament estable i sostenible.<\/span><\/p>\n<h3><b>Qualitat de l\u2019aire interior i salut dels usuaris<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">L\u2019auditori disposa d\u2019un sistema de ventilaci\u00f3 dissenyat segons el RITE (IT 1.1.4.2), assegurant aportacions adequades d\u2019aire exterior i evitant l\u2019acumulaci\u00f3 de contaminants en espais d\u2019alta ocupaci\u00f3 com sales de concerts, camerinos i aules d\u2019assaig.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Aix\u00f2 contribueix no nom\u00e9s a l\u2019estalvi energ\u00e8tic, sin\u00f3 tamb\u00e9 al benestar i la salut d\u2019artistes, treballadors i p\u00fablic.<\/span><\/p>\n<h3><b>Energia solar integrada en l\u2019arquitectura<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">At\u00e8s que l\u2019ampliaci\u00f3 supera els 3.000 m\u00b2, el projecte incorpora una instal\u00b7laci\u00f3 fotovoltaica segons el CTE:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pot\u00e8ncia total prevista: 100 kW<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Instal\u00b7laci\u00f3 actual: 40 kW<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Nova ampliaci\u00f3: 60,35 kW addicionals<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">142 m\u00f2duls fotovoltaics de 425 Wp<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ubicaci\u00f3: coberta oest (30 x 13 m)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inclinaci\u00f3: 6\u00ba | Orientaci\u00f3: 83\u00ba<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Aquesta instal\u00b7laci\u00f3 permetr\u00e0 a l\u2019auditori generar una part significativa del seu consum el\u00e8ctric de manera neta i renovable.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><b>Infraestructura el\u00e8ctrica robusta i eficient<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">L\u2019ampliaci\u00f3 no ha requerit augmentar la pot\u00e8ncia contractada, optimitzant l\u2019\u00fas dels dos transformadors existents de 630 kVA. S\u2019han adaptat i sectoritzat els quadres el\u00e8ctrics per millorar la gesti\u00f3 energ\u00e8tica i la seguretat operativa, incloent un refor\u00e7 del grup electr\u00f2gen amb un m\u00f2dul addicional de 120 kVA.<\/span><\/p>\n<p><b>Certificaci\u00f3 energ\u00e8tica: Classe A<\/b><\/p>\n<p><span style=\"font-weight: 400;\">El resultat final d\u2019aquest conjunt d\u2019estrat\u00e8gies de disseny \u00e9s excel\u00b7lent:<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span> <b>\ud83d\udc49 Certificaci\u00f3 Energ\u00e8tica A<\/b><b><br \/>\n<\/b><b> \ud83d\udc49 Emissions: 2,45 kg CO\u2082\/m\u00b2\u00b7any<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Aquest valor situa l\u2019Auditori Maestro Padilla entre els edificis culturals m\u00e9s eficients energ\u00e8ticament d\u2019Andalusia.<\/span><\/p>\n<h3><b>Un model replicable d\u2019arquitectura cultural sostenible<\/b><\/h3>\n<p>L\u2019ampliaci\u00f3 de l\u2019Auditori Maestro Padilla no \u00e9s nom\u00e9s una millora arquitect\u00f2nica, sin\u00f3 un exemple de com l\u2019enginyeria i l\u2019arquitectura poden treballar conjuntament per crear equipaments p\u00fablics d\u2019alt rendiment ambiental.<\/p>\n<p><span style=\"font-weight: 400;\">Amb aquest projecte, a Aiguasol reafirmem el nostre comprom\u00eds amb la descarbonitzaci\u00f3 del parc edificatori, la integraci\u00f3 d\u2019energies renovables i el confort i la salut de les persones. Un auditori preparat per al futur, en una ciutat compromesa amb la sostenibilitat.<\/span>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A Aiguasol hem liderat el disseny integral de les instal\u00b7lacions de l\u2019Auditori Maestro Padilla amb un enfocament clar: minimitzar el consum energ\u00e8tic, maximitzar l\u2019\u00fas d\u2019energies renovables i garantir el confort i la qualitat ambiental interior de l\u2019espai.<\/p>\n","protected":false},"author":579,"featured_media":148563,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"slim_seo":{"title":"L\u2019ampliaci\u00f3 de l\u2019Auditori Maestro Padilla: una estrat\u00e8gia en efici\u00e8ncia energ\u00e8tica i sostenibilitat - Aiguasol","description":"A Aiguasol hem liderat el disseny integral de les instal\u00b7lacions de l\u2019Auditori Maestro Padilla amb un enfocament clar: minimitzar el consum energ\u00e8tic, maximitza"},"_slim_seo_primary_term_portfolio_category":0,"footnotes":""},"portfolio_category":[149,183,147,146],"class_list":["post-147889","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio_category-energia-edificacio-ca","portfolio_category-qualitat-ambiental-interior","portfolio_category-rehabilitacio-energetica-ca","portfolio_category-edificis-nzeb-i-certificacio-energetica-ca"],"_links":{"self":[{"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/portfolio\/147889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/users\/579"}],"replies":[{"embeddable":true,"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/comments?post=147889"}],"version-history":[{"count":0,"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/portfolio\/147889\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/media\/148563"}],"wp:attachment":[{"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/media?parent=147889"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/aiguasol.coop\/ca\/wp-json\/wp\/v2\/portfolio_category?post=147889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}